2018-06-04
|
O
|
Some of the well head pumps were installed to the motors incorrectly causing damage to the pumps. The splines need to be aligned BEFORE the two parts are tightened.
|
NA
|
NA
|
|
2018-06-04
|
O
|
Review GW monitoring wells with LNAPL and label those where PCB concentrations may be > 50ppm on inside of well lid to inform field staff upon access.
|
NA
|
NA
|
|
2018-06-01
|
O
|
Multi-function printer intermittently not receiving faxes. Printer has also stopped printing from USB drives. Replacement ordered
|
NA
|
NA
|
|
2018-05-31
|
O
|
Could not access PW23, PW24 or PW28 for LNAPL removal due to Skyjack racks/equipment blocking access.
|
NA
|
NA
|
|
2018-05-30
|
O
|
PW30 overload tripped. Attempted reset but overload tripped again. Motor will be diagnosed at upcoming pump change event.
|
NA
|
NA
|
|
2018-05-29
|
O
|
SW1-95 autosampler did not collect sufficient sample volume to fill sample bottles. Technician manually ran autosampler until sufficient volume could be obtained.
|
NA
|
NA
|
|
2018-05-25
|
O
|
Pump change event delayed until June 7th as Skyjack are not able to move their equipment in time even though adequate notice was given.
|
NA
|
NA
|
|
2018-05-22
|
N
|
While staff was turning left into site from Woodlawn Rd. on amber signal, vehicle from behind opposing left-turning vehicle ran the light (turning red) without clear forward view. Narrowly missed hitting right-rear of staff vehicle.
|
NA
|
NA
|
|
2018-05-21
|
O
|
Power loss- treatment system offline, notified via automated callout. Remotely restarted at 1145 pm.
|
NA
|
NA
|
|
2018-05-16
|
O
|
Observed fire extinguishers hadn’t been inspected for current month. Reminded employee responsible to complete task.
|
NA
|
NA
|
|
2018-05-15
|
O
|
Sheen observed entering inlet of SWMP. Contained behind river boom in forebay.
|
NA
|
NA
|
|
2018-05-09
|
O
|
A car was parked by our entrance partially blocking it.
|
NA
|
NA
|
|
2018-05-02
|
O
|
Media vessel pressure sensor valve partially closed causing erroneous reading- valve opened.
|
NA
|
NA
|
|
2018-04-26
|
O
|
Guelph police visited site to investigate squater camp observed in North property woods. The incident reference on their files is: GU18021467. One individual was found at the camp and arrested on prior warrant for petty crime committed elsewhere.
|
NA
|
NA
|
|
2018-04-24
|
O
|
Pergola near the pond collapsed due to high winds; to remove wooden structure for disposal.
|
NA
|
NA
|
|
2018-04-24
|
O
|
GE fences were cut likely by people moving their items into the North Property wetlands. Fence to be repaired.
|
NA
|
NA
|
|
2018-04-24
|
O
|
Field staff member tripped on a branch and fell while taking water levels in the wetland area of the site. No injuries sustained.
|
NA
|
NA
|
|
2018-04-24
|
O
|
Field staff installed high-visibility flex stakes to mark the location of three flush-mount wells in areas that get typically covered by mud, snow or vehicles.
|
NA
|
NA
|
|
2018-04-24
|
O
|
GW field staff found a camp set up by squatters while taking groundwater level measurements in the north property. Staff instructed to leave area immediately. The findings were reported to GE.
|
NA
|
NA
|
|
2018-04-24
|
O
|
MW north of Site inaccessible pending resolution of ongoing presence of squatters - five wells could not be sampled as a result.
|
NA
|
NA
|
|
2018-04-24
|
N
|
Encountered squatter camp in north property. Potential weapons observed at camp including slingshots, pellet handgun, axes, chainsaw and knives. Squatters hid in surrounding bush.
|
NA
|
NA
|
|
2018-04-23
|
O
|
Wells on the front lawn of the property which were originally flush-mounted have been found to have a large portion of their casing exposed. Repairs will be needed to properly secure the integrity of the well and prevent injuries to the public or staff.
|
NA
|
NA
|
|
2018-04-20
|
O
|
Air exhaust blower abnormally loud. Purchased grease gun to grease bearing fittings.
|
NA
|
NA
|
|
2018-04-17
|
O
|
Coffee truck and congregating Skyjack employees blocking new entrance and fire route. Z. Oliveira (Skyjack) instructed Skyjack security to make sure truck stays away from property.
|
NA
|
NA
|
|
2018-04-17
|
O
|
Boom truck parking and rutting through mud-pit of the driveway island between GE & ABB plants while Z. Oliveria (Skyjack) and AECOM staff were reviewing area for well decommissioning. Z. Oliveria instructed truck to park instead in front of the gate between the two properties once the coffee truck had left and freed up an access route for AECOm staff.
|
NA
|
NA
|
|
2018-04-12
|
O
|
Coffee truck blocking new entrance to site serving Skyjack employees. Instructed operator to leave and not park there again.
|
NA
|
SkyJack
|
|
2018-04-06
|
O
|
During routine property check, observed cut section of agricultural fence that restricts access to the north wetlands from the rail corridor. Fence temporarily repaired and no tresspassing sign placed. Permanent repair to be completed.
|
NA
|
NA
|
|
2018-04-05
|
O
|
During pump change out at PW24, hydraulic fluid leak from drill rig • Approx. 1L released on to frozen gravel • Contained by spill pan once safe to position the spill pan • Did not enter CB or PW; ground frozen and oil contained at surface • Impacted gravel shoveled into drum
|
NA
|
NA
|
|
2018-04-05
|
O
|
PW38 runs for approximately 20 minutes before overload trips. Suspected cause is accumulated sediment at bottom of well. Well cleanout to be scheduled.
|
NA
|
NA
|
|
2018-04-05
|
O
|
Effluent sample analyzed by Maxxam had a resultant concentration of 460µg/L. Based on this result the second bottle was analyzed and out of caution immediately collected another outlet sample and shut down the system. The second bottle from the initial sampling event was ND and the second sample collected was also ND. Suspected lab error.
|
NA
|
NA
|